FFmpeg 7.0.2
Since* 4.1
#

Generate a sinc kaiser-windowed low-pass, high-pass, band-pass, or band-reject FIR coefficients.

The resulting stream can be used with afir filter for filtering the audio signal.

The filter accepts the following options:

sample_rate, r

Set sample rate, default is 44100.

nb_samples, n

Set number of samples per each frame. Default is 1024.

hp

Set high-pass frequency. Default is 0.

lp

Set low-pass frequency. Default is 0. If high-pass frequency is lower than low-pass frequency and low-pass frequency is higher than 0 then filter will create band-pass filter coefficients, otherwise band-reject filter coefficients.

phase

Set filter phase response. Default is 50. Allowed range is from 0 to 100.

beta

Set Kaiser window beta.

att

Set stop-band attenuation. Default is 120dB, allowed range is from 40 to 180 dB.

round

Enable rounding, by default is disabled.

hptaps

Set number of taps for high-pass filter.

lptaps

Set number of taps for low-pass filter.