Apply an Adaptive Temporal Averaging Denoiser to the video input.
The filter accepts the following options:
- 0a
-
Set threshold A for 1st plane. Default is 0.02. Valid range is 0 to 0.3.
- 0b
-
Set threshold B for 1st plane. Default is 0.04. Valid range is 0 to 5.
- 1a
-
Set threshold A for 2nd plane. Default is 0.02. Valid range is 0 to 0.3.
- 1b
-
Set threshold B for 2nd plane. Default is 0.04. Valid range is 0 to 5.
- 2a
-
Set threshold A for 3rd plane. Default is 0.02. Valid range is 0 to 0.3.
- 2b
-
Set threshold B for 3rd plane. Default is 0.04. Valid range is 0 to 5.
Threshold A is designed to react on abrupt changes in the input signal and threshold B is designed to react on continuous changes in the input signal.
- s
-
Set number of frames filter will use for averaging. Default is 33. Must be odd number in range [5, 129].